On March 26, 2020, according to Decree 159-2020 published on March 11, 2020 in the Gazette officielle du Québec, the Regulation respecting occupational health and safety (RSST, RLRQ, c. S-2.1, r. 13) is amended in Appendix 1. These regulatory changes have not yet been incorporated into the current Substance Data Sheets of the Sampling Guide for Air Contaminants in the Workplace. An update is currently underway and will be available as soon as possible. Consequently, the information contained in the data sheets of substances modified or added in Decree 159-2020 is probably inaccurate or incomplete. Please contact our client service: [email protected] for further information.

Starch(Pt)

French name in the regulation: Amidon(Pt)
CAS : 9005-25-8

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 10 - 1 , Pt
STEV - - - -
Ceiling - - - -
Simple asphyxiant Percutaneous
Minimum exposure Sensitizer
Prohibited use Prohibited recirculation
Carcinogenicity

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Starch(Pt)

Analysis:

Mesure pondérales des poussières totales

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
902 Preweighed PVC filter, 37 mm, 5 µm

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision: 4,0
Minimum reported value 25 µg
Remarks: Additional information is available in Info-Labo 91-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Mesure pondérales des poussières totales

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
914 PVC filter, 25 mm, preweighed, 5 µm

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision: 4,0
Minimum reported value 25 µg
Remarks: Additional information is available in Info-Labo 91-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Mesure pondérales des poussières totales

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
997 PVC filter, 37 mm 5 µm, preweighed, 3-part

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision: 4,0
Minimum reported value 25 µg
Remarks: Additional information is available in Info-Labo 91-03. The weight measurement method for dusts is by definition non-specific.