IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Phosphorus oxychloride  

French name in the regulation: Phosphore, oxychlorure de
CAS : 10025-87-3

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 0,1 0,63 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Phosphorus oxychloride

Analysis:

Phosphore, oxychlorure de

Recommended method by the IRSST:
Method: OSHA - IMIS2094
Sampling device: Glass fritted tip impinger containing 10 mL of a solution of sodium carbonate and sodium bicarbonate
Parameters:
Flow rate: 1 L/min
TWA sampling volume: 240 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Ion chromatography with conductivity detection (IC-CD)
OSHA, Chemical Information Manual. IMIS2094: Phosphorus Oxychloride, 1993.