IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Cellulose (paper fibres) (Pt)  

French name in the regulation: Cellulose (fibres de papier) (Pt)
CAS : 9004-34-6

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 10 - 1; Pt
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1C : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Cellulose (paper fibres)(Pt)

Analysis:

Weight measurement for dusts on encapsulated filter

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
910 PVC-37 mm, 5 mm preweighed capsule (Accu-Cap)

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.