IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

VM&P Naphtha  

French name in the regulation: Naphta VM & P
CAS : 8032-32-4

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 300 1370 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: VM&P Naphtha

Analysis:

Naphta VM et P

Method: IRSST - 29-1
Sampling device:
Sampling media required:
#IRSSTDescription
2120 Activated charcoal tube 100/50 mg

Parameters:
Flow rate: Max: 0,2 L/min
TWA sampling volume: 10 L
STEL sampling volume: -
Remarks: A process sample must be supplied.
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 1,1
Minimum reported value: 170 µg
IRSST. "Analyse du naphta VM et P dans l'air". Méthode 29-1. Méthodes analytiques. Montréal: IRSST, 1992.