IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

2-Nitropropane  

French name in the regulation: Nitro-2 propane
CAS : 79-46-9

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 10 36 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity C2 Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposure Explosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: 2-Nitropropane

Analysis:

Nitro-2 propane

Recommended method by the IRSST:
Method: OSHA - 46
Sampling device: XAD-4 tube 80/40 mg
Parameters:
Flow rate: 0,1 L/min
TWA sampling volume: 4 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Gas chromatography with flame ionization detection (GC-FID)
OSHA, Chemical information Manual, method 46, 1-Nitropropane and 2-Nitropropane, 1984.