OHS Research
Research at the IRSST
Reference Framework
Scientists Directory
+
Publications and Tools
IRSST's Production
Magazine and Newsletter
Scientific Watch
Documentation Center
Useful Links
-
Laboratory Services
Laboratories
-
Analysis and Testing Services
Laboratory Methods
Masks Efficacy Evaluation
Workplace Air Contaminants
Slip Resistance Test for Protective Footwear
Loan, Calibration and Repairs
+
Recognition Programs
+
CQ Fibres
Quality Control of Fiber Counts
+
CQ Vrac
Recognized Laboratories
Interlaboratory quality
control program
Guides and Tools
Instruments and Sampling Material
Register
+
Research Fund and Partnerships
Research Fund and Partnerships
Grants
+
Scholarships
Master’s Scholarship and Supplement
Doctoral Scholarship and Supplement
Postdoctoral Fellowship
Research partnerships
+
Institute
+
About
Activity Report
Organization Chart
Policies
Research Ethics Committee
Strategic Plan
Historical Overview
Press Room (french only)
Work at the IRSST (french only)
Search
Contact us
|
Stay in touch
IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail
Contact us
Press Room
Careers
IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail
OHS Research
Research at the IRSST
Reference Framework
Scientists Directory
Publications and Tools
IRSST's Production
Magazine and Newsletter
Scientific Watch
Documentation Center
Useful Links
Laboratory Services
Laboratories
Analysis and Testing Services
Laboratory Methods
Masks Efficacy Evaluation
Workplace Air Contaminants
Slip Resistance Test for Protective Footwear
Loan, Calibration and Repairs
Recognition Programs
CQ Fibres
Quality Control of Fiber Counts
CQ Vrac
Recognized Laboratories
Interlaboratory quality
control program
Guides and Tools
Instruments and Sampling Material
Register
Research Fund and Partnerships
Research Fund and Partnerships
Grants
Scholarships
Master’s Scholarship and Supplement
Doctoral Scholarship and Supplement
Postdoctoral Fellowship
Research partnerships
Institute
About
Activity Report
Organization Chart
Policies
Research Ethics Committee
Strategic Plan
Historical Overview
Press Room (french only)
Work at the IRSST (french only)
substance
Laboratory Services
>
Analysis and Testing Services
>
Workplace Air Contaminants
>
substance
August 28, 2025
Isobutyl alcohol
French name in the regulation:
Alcool isobutylique
CAS :
78-83-1
Exposure Standards in RROHS regulation
Permissible exposure values (PEV)
ppm
mg/m
3
f/cc
Notes
TWAEV
50
152
-
-
STEV
-
-
-
-
Ceiling
-
-
-
-
Carcinogenicity
Sensitizer
Simple asphyxiant
Percutaneous
Prohibited use
Prohibited recirculation
Minimum exposure
Explosion hazard
Ototoxic
TWA adjustment for unusual work schedules
1B
: No adjustment
CNESST – Toxicological Index Service
Consult REPTOX file:
Isobutyl alcohol
Analysis:
Alcool isobutylique
Method: IRSST - 278-1
Sampling protocol
Sampling device:
Sampling media required:
#IRSST
Description
2120
Activated charcoal tube 100/50 mg
Parameters:
Flow rate: Max: 0.2 L/min
TWA sampling volume: 10 L
STEL sampling volume: -
Analytical protocol
Principle:
Gas chromatography with flame ionization detection (GC-FID)
Precision (%):
6,4
Minimum reported value:
75 µg
Remarks:
The analysis can be done by gas chromatography coupled with mass spectrometry (GC-MS, IRSST method #369); in this case the analytical uncertainty (CVa) is 7.6%.
Reference
IRSST. "Analyse de l'alcool isobutylique dans l'air". Méthode 278-1. Non publiée.
Isobutyl alcohol
Method: IRSST - 415
Sampling protocol
Sampling device:
Sampling media required:
#IRSST
Description
2197
Anasorb 747 tubes (2) 400/200 mg in series
Parameters:
Flow rate: 0.05 L/min
TWA sampling volume: 12 L
STEL sampling volume: -
Remarks:
At the end of sampling, the front tube must be separated from the back tube to avoid migration. Reseal each end of the tubes. Additional information is also available in french in "consigne d'utilisation I-MAT-039". Isobutyl alcohol must be sampled specifically because of the sampling device used.
Analytical protocol
Principle:
Gas chromatography with flame ionization detection (GC-FID)
Precision (%):
0,5
Minimum reported value:
30 µg
Remarks:
However, simultaneous sampling and analysis of Methyl alcohol, Ethyl alcohol, sec-Butyl alcohol, n-propyl alcohol, Isopropyl alcohol and n-Butyl alcohol is possible.
Reference
IRSST. Détermination des alcools prélevés sur tubes de charbon activé synthétique dans l'air (non publié)
Isobutyl alcohol
Method: IRSST - 416
Sampling protocol
Sampling device:
Sampling media required:
#IRSST
Description
2696
566AT passive dosimeter
Parameters:
Flow rate: 0,0107 L/min
TWA sampling volume: -
STEL sampling volume: -
Remarks:
For the monitors, the flow must be considered as being a sampling rate.
Analytical protocol
Principle:
Gas chromatography with flame ionization detection (GC-FID)
Precision (%):
2,7
Minimum reported value:
8 µg
Reference
IRSST. "Dosage des composés organiques volatils dans l'air par dosimétrie passive". Méthode 416. Non publiée.
×