IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Zinc chloride, fume  

French name in the regulation: Zinc, chlorure de (fumées)
CAS : 7646-85-7

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 1 - -
STEV - 2 - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

II : Daily adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Zinc chloride, fume

Analysis:

Zinc (exprimé en Zn)

Method: IRSST - 362
Sampling device:
Sampling media required:
#IRSSTDescription
913 MCE filter, 37 mm, 0,8µm, preweighed

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: Refer to the information in InfoLABO 2018-11 regarding limitations related to gravimetric measurement obtained through the use of these cassette. For surface wipe sampling, contact Laboratory Customer Service.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
Precision (%): 2,9
Minimum reported value: 1 µg
Remarks: This method allows the analysis of chemical elements present in the sample without distinguishing the different chemical forms. The analytical results are expressed as total zinc. A stoichiometric factor must be applied.
IRSST, Détermination de métaux dans l'air des lieux de travail par spectrométrie de masse avec plasma à couplage inductif (ICP-MS), Méthodes analytiques, / MA-362-fr, Montréal, IRSST, 2010, 17 pages.

Zinc (exprimé en Zn)

Method: IRSST - 362
Sampling device:
Sampling media required:
#IRSSTDescription
916 MCE filter, 25 mm, 0.8µm, preweighed

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: Refer to the information in InfoLABO 2018-11 regarding limitations related to gravimetric measurement obtained through the use of these cassette. For surface wipe sampling, contact Laboratory Customer Service.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
Precision (%): 2,9
Minimum reported value: 1 µg
Remarks: This method allows the analysis of chemical elements present in the sample without distinguishing the different chemical forms. The analytical results are expressed as total zinc. A stoichiometric factor must be applied.
IRSST, Détermination de métaux dans l'air des lieux de travail par spectrométrie de masse avec plasma à couplage inductif (ICP-MS), Méthodes analytiques, / MA-362-fr, Montréal, IRSST, 2010, 17 pages.

Zinc Solu-Sert

Method: IRSST - 394
Sampling device:
Sampling media required:
#IRSSTDescription
990 25-mm Solu-Sert MCE filter

Parameters:
Flow rate: 1.5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: For surface wipe sampling, contact Laboratory Customer Service.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
Precision (%): 3,4
Minimum reported value: 1 µg
Remarks: This method allows the analysis of chemical elements present in the sample without distinguishing the different chemical forms. The analytical results are expressed as total zinc.
IRSST. Détermination de la concentration des métaux dans l’air par ICP-MS – Prélèvement effectué sur filtre encapsulé digérable Solu Sert.

Zinc Solu-Sert

Method: IRSST - 394
Sampling device:
Sampling media required:
#IRSSTDescription
992 37-mm Solu-Sert MCE filter

Parameters:
Flow rate: 1.5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: For surface wipe sampling, contact Laboratory Customer Service.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
Precision (%): 3,4
Minimum reported value: 1 µg
Remarks: This method allows the analysis of chemical elements present in the sample without distinguishing the different chemical forms. The analytical results are expressed as total zinc.
IRSST. Détermination de la concentration des métaux dans l’air par ICP-MS – Prélèvement effectué sur filtre encapsulé digérable Solu Sert.