IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Iodoform  

French name in the regulation: Iodoforme
CAS : 75-47-8

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 0,6 10 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

II : Daily adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Iodoform

Analysis:

Iodoforme

Recommended method by the IRSST:
Method: OSHA - IMIS1517
Sampling device: Glass fiber filter in series with an XAD-4 tube
Parameters:
Flow rate: 0,1 L/min
TWA sampling volume: 10 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Gas chromatography with electron-capture detection (GC-ECD)
OSHA, Chemical Information Manual. IMIS1517: Iodoform, 1992.