IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Nitrous oxide  

French name in the regulation: Azote, protoxyde d'
CAS : 10024-97-2

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 50 90 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Nitrous oxide

Analysis:

Azote, protoxyde d'

Method: IRSST - 320-1
Sampling device:
Parameters:
Flow rate: -
TWA sampling volume: -
STEL sampling volume: -
Principle: Direct reading instrument-Photoacoustic detection (DRI-PAD)
Remarks: The minimum reported value is 0.09 mg/m³ (0.05 ppm).
IRSST. "Analyse de l'oxyde de carbone, le dixoyde de carbone et le protoxyde d'azote". Méthode 320-1. Non publiée.

Azote, protoxyde d'

Recommended method by the IRSST:
Method: NIOSH - 6600
Sampling device: Passive monitor ACS # N-10
Parameters:
Flow rate: -
TWA sampling volume: -
STEL sampling volume: -
Remarks: Contact the IRSST before sampling. Stable for 2 weeks after the sampling.
Principle: Direct reading instrument-Photoacoustic detection (DRI-PAD)
NIOSH Manual of Analytical Methods, 4th ed., Method 6600 : Nitrous Oxide, 1994.