IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Endrin  

French name in the regulation: Endrine
CAS : 72-20-8

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 0,1 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

II : Daily adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Endrin

Analysis:

Endrine

Recommended method by the IRSST:
Method: NIOSH - 5519
Sampling device: Mixed cellulose ester filter in series with a Chromosorb-102 tube
Parameters:
Flow rate: 0,5-1 L/min
TWA sampling volume: 120 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Gas chromatography with electron-capture detection (GC-ECD)
NIOSH Manual of Analytical Methods, 4th ed, Method 5519 : Endrin, 1994.