IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Methyl chloroform  

French name in the regulation: Méthylchloroforme
CAS : 71-55-6
Synonyms: Trichloro-1,1,1 éthane

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 350 1910 - -
STEV 450 2460 - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

II : Daily adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Methyl chloroform

Analysis:

Méthylchloroforme

Method: IRSST - 100-1
Sampling device:
Sampling media required:
#IRSSTDescription
2120 Activated charcoal tube 100/50 mg

Parameters:
Flow rate: Max: 0,2 L/min
TWA sampling volume: 6 L
STEL sampling volume: 3 L
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 6,4
Minimum reported value: 450 µg
IRSST. "Analyse du trichloro 1-1-1 éthane dans l'air". Méthodes analytiques. Montréal: IRSST, 1988.

Methyl chloroform

Method: IRSST - 416
Sampling device:
Sampling media required:
#IRSSTDescription
2696 566AT passive dosimeter

Parameters:
Flow rate: 0,00793 L/min
TWA sampling volume: -
STEL sampling volume: -
Remarks: For the monitors, the flow must be considered as being a sampling rate.
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 2,7
Minimum reported value: 80 µg
IRSST. "Dosage des composés organiques volatils dans l'air par dosimétrie passive". Méthode 416. Non publiée.