IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Dicyclopentadienyl iron  

French name in the regulation: Dicyclopentadiényle de fer
CAS : 102-54-5

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 10 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1C : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Dicyclopentadienyl iron

Analysis:

Dicyclopentadiényle de fer

Recommended method by the IRSST:
Method: -
Sampling device:
Parameters:
Flow rate: -
TWA sampling volume: -
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.

Remarks: IRSST method 362 is for iron and can be adapted to iron dicyclopentadiene. IRSST method 48-1 (gravimetric analysis) can also be used, given the standard of 10 mg/m³.