IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Triglycidyl isocyanurate (TGIC) (mixed isomers)  

French name in the regulation: Isocyanurate de triglycidyle (TGIC) (mélange d'isomères)
CAS : 2451-62-9

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 0,05 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service


Analysis:

Isocyanurate de triglycidyle (TGIC)

Method: IRSST - 364
Sampling device:
Sampling media required:
#IRSSTDescription
910 PVC-37 mm, 5 mm preweighed capsule (Accu-Cap)

Parameters:
Flow rate: 2,0 L/min
TWA sampling volume: 240 L
STEL sampling volume: -
Principle: High performance liquid chromatography with mass spectrometry (HPLC-MS)
Precision (%): 4,3
Minimum reported value: 0,5 µg
Remarks: This method gives a result expressed in total triglycidyl isocyanurate, corresponding to the mixture of the alpha and beta isomers. A gravimetric result of the total dust can be supplied on request.
IRSST. "Analyse du triglycéryl isocyanurate (TGIC) dans l'air". Méthode 364. Non publiée.