IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

o-Chlorostyrene  

French name in the regulation: o-Chlorostyrène
CAS : 2039-87-4

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 50 283 - -
STEV 75 425 - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

IV : Daily or weekly adjustment ( the more stringent of the two)

CNESST – Toxicological Index Service

Consult REPTOX file: o-Chlorostyrene

Analysis:

o-Chlorostyrène

Recommended method by the IRSST:
Method: NIOSH - 1003
Sampling device: Activated charcoal tube 100/50 mg
Parameters:
Flow rate: 0,01-0,2 L/min
TWA sampling volume: 20 L
STEL sampling volume: 3 L
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Gas chromatography with flame ionization detection (GC-FID)
Remarks: NIOSH method 1003 is for halogenated hydrocarbons, which does not specifically include o-chlorostyrene.
NIOSH Manual of Analytical Methods, 4th ed, Method 1003, Hydrocarbons halogenated, 2003.