IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Nitrogen monoxide  

French name in the regulation: Azote, monoxyde d'
CAS : 10102-43-9

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 25 31 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

II : Daily adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Nitrogen monoxide

Analysis:

Azote, monoxyde d'

Method: IRSST - 06-A
Sampling device:
Parameters:
Flow rate: -
TWA sampling volume: -
STEL sampling volume: -
Remarks: Refer to the user's guide accompanying the instrument.
Principle: Direct reading instrument-Electrochemical cell (DRI-elec)
Remarks: Nitric oxide is quantified in the field with a direct-reading instrument (DRI). The minimum reported value is 1.2 mg/m³ (1 ppm). The reference method corresponds to calibration of the DRI.. Azote monoxyde quantified with DRI.
IRSST. "Étalonnage d'un instrument à lecture directe pour la mesure du monoxyde d'azote dans l'air". Méthode 06-A. Non-publiée.