IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Morpholine  

French name in the regulation: Morpholine
CAS : 110-91-8

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 20 71 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Morpholine

Analysis:

Morpholine

Method: IRSST - 363
Sampling device:
Sampling media required:
#IRSSTDescription
955 FV filter impregnated with sulfuric acid

Parameters:
Flow rate: 1 L/min
TWA sampling volume: 15 L
STEL sampling volume: -
Remarks: The sample is stable for 2 weeks at 4°C.
Principle: High performance liquid chromatography with mass spectrometry (HPLC-MS)
Precision (%): 7,6
Minimum reported value: 7,5 µg
IRSST. "Détermination des amines dans l'air par LC-MS". Méthode 363. Méthodes analytiques. Montréal: IRSST, 2021.