IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

4-Nitrodiphenyl  

French name in the regulation: Nitro-4 diphényle
CAS : 92-93-3

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - - - -
STEV - - - -
Ceiling - - - -
Carcinogenicity C1 Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposure Explosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: 4-Nitrodiphenyl

Analysis:

Nitro-4 diphényle

Recommended method by the IRSST:
Method: OSHA - PV2082
Sampling device: OVS-2 tube with XAD-2 and glass fiber filter
Parameters:
Flow rate: 1,0 L/min
TWA sampling volume: 240 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: High performance liquid chromatography with UV detection (HPLC-UV)
OSHA, 4-Nitrodiphenyl, Chemical Information Manual. PV2082, 1994.