IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Sulfur monochloride  

French name in the regulation: Soufre, monochlorure de
CAS : 10025-67-9

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - - - -
STEV - - - -
Ceiling 1 5,5 - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1A : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Sulfur monochloride

Analysis:

Soufre, monochlorure de

Recommended method by the IRSST:
Method: OSHA - IMIS2320
Sampling device: Glass fritted tip impinger containing deionized water
Parameters:
Flow rate: 1 L/min
TWA sampling volume: 30 L
STEL sampling volume: 15 L
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Ion chromatography with conductivity detection (IC-CD)
OSHA, Chemical Information Manual. IMIS2320: Sulfur Monochloride, 1993.