IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Hexylene glycol  

French name in the regulation: Hexylène glycol
CAS : 107-41-5

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - - - -
STEV - - - -
Ceiling 25 121 - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1A : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Hexylene glycol

Analysis:

Hexylène glycol

Recommended method by the IRSST:
Method: OSHA - PV2101
Sampling device: Activated charcoal tube 100/50 mg
Parameters:
Flow rate: 0,05-0,1 L/min
TWA sampling volume: 3 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Gas chromatography with flame ionization detection (GC-FID)
OSHA, Chemical Information Manual. PV2101 Hexylene glycol, 1988.