IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Paraffin wax, fume  

French name in the regulation: Paraffine, cire de (fumées)
CAS : 8002-74-2

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 2 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Paraffin wax, fume

Analysis:

Paraffine, cire de (fumée)

Recommended method by the IRSST:
Method: OSHA - PV2047
Sampling device: Glass fiber filter
Parameters:
Flow rate: 1 L/min
TWA sampling volume: 100 L
STEL sampling volume: -
Remarks: Contact the IRSST before sampling. The sampling volume can vary from 30 to 960 litres.
Principle: Gas chromatography with flame ionization detection (GC-FID)
OSHA Chemical Information Manual, PV2047 Paraffin wax fumes, 1988.