IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Dichlorofluoromethane  

French name in the regulation: Dichlorofluorométhane
CAS : 75-43-4
Synonyms: Fréon 21

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 10 42 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

IV : Daily or weekly adjustment ( the more stringent of the two)

CNESST – Toxicological Index Service

Consult REPTOX file: Dichlorofluoromethane

Analysis:

Dichlorofluorométhane

Recommended method by the IRSST:
Method: NIOSH - 2516
Sampling device: Two 400/200 mg activated charcoal tubes in series
Parameters:
Flow rate: 0,01-0,05 L/min
TWA sampling volume: 3 L
STEL sampling volume: -
Remarks: Contact the IRSST before sampling. Freon 21.
Principle: Gas chromatography with flame ionization detection (GC-FID)
NIOSH Manual of Analytical Methods, 4th ed., Method 2516 : Dichlorofluoromethane, 1994.