Beryllium [7440-41-7], metal and compounds  

French name in the regulation: Béryllium [7440-41-7], métal et composés
CAS : 7440-41-7

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 0,00015 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity C1 Sensitizer S
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposure Explosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service


Analysis:

Béryllium, Solu-Sert

Method: IRSST - 396
Sampling device:
Sampling media required:
#IRSSTDescription
990 25-mm Solu-Sert MCE filter

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: For surface wipe sampling, contact Laboratory Customer Service.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
Precision (%): 1,24
Minimum reported value: 0,00025 µg
Remarks: Specific sampling must be carried out for this substance. This method allows the analysis of chemical elements present in the sample without distinguishing the different chemical forms. The analytical results are expressed as total beryllium.
IRSST. Détermination de la concentration en béryllium dans l’air par ICP-MS – Prélèvement effectué sur filtre encapsulé digérable Solu Sert

Béryllium, Solu-Sert

Method: IRSST - 396
Sampling device:
Sampling media required:
#IRSSTDescription
992 37-mm Solu-Sert MCE filter

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: For surface wipe sampling, contact Laboratory Customer Service.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
Precision (%): 1,24
Minimum reported value: 0,00025 µg
Remarks: Specific sampling must be carried out for this substance. This method allows the analysis of chemical elements present in the sample without distinguishing the different chemical forms. The analytical results are expressed as total beryllium.
IRSST. Détermination de la concentration en béryllium dans l’air par ICP-MS – Prélèvement effectué sur filtre encapsulé digérable Solu Sert