IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Rhodium [7440-16-6], Soluble compounds (as Rh)  

French name in the regulation: Rhodium, Composés solubles
CAS : 7440-16-6

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 0,001 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service


Analysis:

Rhodium, Composés solubles (exprimé en Rh)

Recommended method by the IRSST:
Method: ASTM - D7439-08
Sampling device: Mixed cellulose ester filter
Parameters:
Flow rate: 1-5 L/min
TWA sampling volume: 480 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
ASTM, Determination of elements in airborne particulate matter by inductively coupled plasma-mass spectrometry, 2008.