Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 1 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer S
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Platinum, Metal

Analysis:

Platine, Métal

Recommended method by the IRSST:
Method: OSHA - ID121
Sampling device: Mixed cellulose ester filter
Parameters:
Flow rate: 2 L/min
TWA sampling volume: 960 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Inductively coupled plasma spectrometry (ICP-MS)
OSHA Analytical Methods Manual. Method ID121. Metals & metalloid particulates in workplace atmosphere, 2002.