IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Chromium VI, water soluble inorganic compounds  

French name in the regulation: Chrome VI, composés inorganiques hydro-solubles

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 0,005 - -
STEV - - - -
Ceiling - - - -
Carcinogenicity C1 Sensitizer R,D
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposure Explosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service


Analysis:

Chrome VI hydrosolubles

Method: IRSST - 365
Sampling device:
Sampling media required:
#IRSSTDescription
976 25mm quartz filter in a conical cassette

Parameters:
Flow rate: 1.5 L/min
TWA sampling volume: 360 L
STEL sampling volume: -
Principle: Ion chromatography with visible detection (IC-VIS)
Precision (%): 1,0
Minimum reported value: 0,04 µg
Remarks: The analytical results are expressed as total water-soluble chromium VI. Surface tests for chromates can be carried out, and the required equipment (kit #2625) is available at the IRSST. Extraction delay of 8 days for welding fumes and 10 days for the other processes following the sampling date. Ship all samples by rapid courier within a period not exceeding 24 hours after sampling. Any substance that produces a response on the detector at 540 nm and that has a retention time similar to Cr VI is a potential interference.
IRSST. Détermination des composés inorganiques du chrome hexavalent hydrosolubles et hydroinsolubles dans l'air des lieux de travail, Méthodes analytiques, méthode 365, Montréal, IRSST, 2009, 17 pages.

Chrome VI hydrosolubles dans aérosols acides

Method: IRSST - 365
Sampling device:
Sampling media required:
#IRSSTDescription
977 25mm coated quartz filter in a conical cassette

Parameters:
Flow rate: 1.5-4 L/min
TWA sampling volume: 360 L
STEL sampling volume: -
Remarks: For chrome VI in acid aerosol.
Principle: Ion chromatography with visible detection (IC-VIS)
Precision (%): 1,5
Minimum reported value: 0,04 µg
Remarks: The analytical results are expressed as total water-soluble chromium VI. Surface tests for chromates can be carried out, and the required equipment (kit #2625) is available at the IRSST. The coated sampling cassette 977 is stable one month. Extraction delay of 14 days following the sampling date. Ship all samples by rapid courier within a period not exceeding 24 hours after sampling.
IRSST. Détermination des composés inorganiques du chrome hexavalent hydrosolubles et hydroinsolubles dans l'air des lieux de travail, Méthodes analytiques, méthode 365, Montréal, IRSST, 2009, 17 pages.