IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Sulfur pentafluoride  

French name in the regulation: Soufre, pentafluorure de
CAS : 5714-22-7

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - - - -
STEV - - - -
Ceiling 0,01 0,1 - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1A : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Sulfur pentafluoride

Analysis:

Soufre, pentafluorure de

Recommended method by the IRSST:
Method: NIOSH - 7902
Sampling device: Cellulose ester filter followed by a pretreated cellulose pad
Parameters:
Flow rate: 1-2 L/min
TWA sampling volume: 800 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Ion specific electrode (SE)
Remarks: NIOSH method 7902 is for aerosol and gas fluorides and can be adapted to this product.
NIOSH Manual of Analytical Methods. 4th ed. Method 7902 : Fluorides, Aerosol and Gas. NIOSH, 1994.