IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Sevoflurane  

French name in the regulation: Sevoflurane
CAS : 28523-86-6

Not in the regulation.


CNESST – Toxicological Index Service

Consult REPTOX file: Sevoflurane

Analysis:

Sevoflurane

Method: IRSST - 355-1
Sampling device:
Sampling media required:
#IRSSTDescription
2190 Anasorb 747 140/70mg

Parameters:
Flow rate: Max: 0,2 L/min
TWA sampling volume: 3 L
STEL sampling volume: -
Remarks: Sevoflurane must be specifically sampled due to the sampling device used and a specific desorption solvent.
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 2,5
Minimum reported value: 30 µg
Remarks: However, simultaneous sampling and analysis of desflurane is possible. A permissible exposure value (of the TWA type) of 80 mg/m³ has been proposed by the Swedish National Board of Occupational Safety and Health.
IRSST. "Analyse du sevoflurane dans l'air". Méthode 355-1. Non publiée.