IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Atrazine and symmetric triazine analogs (Pi)  

French name in the regulation: Atrazine et les triazines symétriques analogues (Pi)
CAS : 1912-24-9

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 2 - Pi
STEV - - - -
Ceiling - - - -
Carcinogenicity C3 Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

II : Daily adjustment

CNESST – Toxicological Index Service


Analysis:

Atrazine

Recommended method by the IRSST:
Method: NIOSH - 5602
Sampling device: OVS-2 tube with XAD-2 and glass fiber filter
Parameters:
Flow rate: 0,2-1 L/min
TWA sampling volume: 480 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis is performed by another laboratory. Please contact the IRSST before sampling. The aerosol phase might be underestimated because the efficiency of the sampling device does not match the inhalable fraction definition. For more information, please contact the IRSST.
Principle: Gas chromatography with electron-capture detection (GC-ECD)
Remarks: Some phosphates may cause interferences during the analysis.
NIOSH, Manual of Analytical Methods, 4th ed., Method 5602, Chlorinated and organonitrogen herbicides, 1998.