IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

m-Xylene-alpha, alpha'-diamine  

French name in the regulation: m-Xylène alpha, alpha'-diamine
CAS : 1477-55-0

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - - - -
STEV - - - -
Ceiling - 0,1 - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1A : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: m-Xylene-alpha, alpha'-diamine

Analysis:

m-Xylène alpha, alpha'-diamine

Recommended method by the IRSST:
Method: OSHA - 105
Sampling device: Two glass fiber filters impregnated with sulfuric acid
Parameters:
Flow rate: 1 L/min
TWA sampling volume: 15 L
STEL sampling volume: -
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: High performance liquid chromatography with UV detection (HPLC-UV)
OSHA, Chemical Information Manual. Méthod 105: m-Xylène-alpha, alpha'-diamine (m-Xylylenediamine, mXDA, 1994.