IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Thiram® (IFV)  

French name in the regulation: Thiram® (IFV)
CAS : 137-26-8

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 0,05 - IFV
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer D
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

III : Weekly adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Thiram®(IFV)

Analysis:

Thiram®

Recommended method by the IRSST:
Method: NIOSH - 5005
Sampling device: Polytetrafluoroethylene (teflon) filter
Parameters:
Flow rate: 1-4 L/min
TWA sampling volume: 400 L
STEL sampling volume: -
Remarks: The recommanded method for Thiram is suitable for the aerosol phase exclusively. The aerosol phase might be underestimated because the efficiency of the sampling device does not match inhalable fraction definition. For more information, please contact the IRSST. This substance is not analyzed by our laboratories. It might be possible that the analysis is performed by another laboratory. Please contact the IRSST before sampling.
Principle: High performance liquid chromatography with UV detection (HPLC-UV)
NIOSH Manual of Analytical Methods. 4th. ed., Method 5005: Thiram, 1994.