IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Perchloroethylene  

French name in the regulation: Perchloroéthylène
CAS : 127-18-4
Synonyms: Tétrachloroéthylène

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV 25 170 - -
STEV 100 685 - -
Ceiling - - - -
Carcinogenicity C3 Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

IV : Daily or weekly adjustment ( the more stringent of the two)

CNESST – Toxicological Index Service

Consult REPTOX file: Perchloroethylene

Analysis:

Perchloroéthylène

Method: IRSST - 140-2
Sampling device:
Sampling media required:
#IRSSTDescription
2120 Activated charcoal tube 100/50 mg

Parameters:
Flow rate: Max: 0,2 L/min
TWA sampling volume: 10 L
STEL sampling volume: 3 L
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 7,3
Minimum reported value: 68 µg
Remarks: The analysis can be done by gas chromatography coupled with mass spectrometry (GC-MS, IRSST method #369); in this case the analytical uncertainty (CVa) is 3.6%.
IRSST. "Analyse du perchloroéthylène". Méthode 140-2. Méthodes analytiques. Montréal: IRSST, 1995.

Perchloroethylene

Method: IRSST - 416
Sampling device:
Sampling media required:
#IRSSTDescription
2696 566AT passive dosimeter

Parameters:
Flow rate: 0,0071 L/min
TWA sampling volume: -
STEL sampling volume: -
Remarks: For the monitors, the flow must be considered as being a sampling rate.
Principle: Gas chromatography with flame ionization detection (GC-FID)
Precision (%): 3,6
Minimum reported value: 8 µg
IRSST. "Dosage des composés organiques volatils dans l'air par dosimétrie passive". Méthode 416. Non publiée.