Portland cement (Pr)  

French name in the regulation: Ciment Portland (Pr)
CAS : 65997-15-1

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 1 - 1; Pr
STEV - - - -
Ceiling - - - -
Carcinogenicity Sensitizer S
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Portland cement(Pr)

Analysis:

Weight measurement for respirable dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
902 Preweighed PVC filter, 37 mm, 5 µm

Parameters:
Flow rate: 1,7 (nylon) 2,75 (GS3) L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: A cyclone is required for sampling. The cassette to be used is directly related to the cyclone used. The GS3 cyclone must be used with cassette 997.
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Weight measurement for respirable dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
914 PVC filter, 25 mm, preweighed, 5 µm

Parameters:
Flow rate: 1,7 (nylon) 2,75 (GS3) L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: A cyclone is required for sampling. The cassette to be used is directly related to the cyclone used. The GS3 cyclone must be used with cassette 997.
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Weight measurement for respirable dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
997 PVC filter, 37 mm 5 µm, preweighed, 3-part

Parameters:
Flow rate: 1,7 (nylon) 2,75 (GS3) L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Remarks: A cyclone is required for sampling. The cassette to be used is directly related to the cyclone used. The GS3 cyclone must be used with cassette 997.
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.