IRSST - Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Ammonium chloride fume  

French name in the regulation: Ammonium, chlorure d' (fumées)
CAS : 12125-02-9

Exposure Standards in RROHS regulation

Permissible exposure values (PEV)
ppm mg/m3 f/cc Notes
TWAEV - 10 - -
STEV - 20 - -
Ceiling - - - -
Carcinogenicity Sensitizer
Simple asphyxiantPercutaneous
Prohibited useProhibited recirculation
Minimum exposureExplosion hazard
Ototoxic

TWA adjustment for unusual work schedules

1B : No adjustment

CNESST – Toxicological Index Service

Consult REPTOX file: Ammonium chloride fume

Analysis:

Ammonium, chlorure d' (fumée)

Recommended method by the IRSST:
Method: OSHA - ID188
Sampling device: Mixed cellulose ester filter
Parameters:
Flow rate: 2 L/min
TWA sampling volume: 960 L
STEL sampling volume: 30 L
Remarks: This substance is not analyzed by our laboratories. It might be possible that the analysis be performed by another laboratory. Please contact the IRSST before sampling.
Principle: Ion chromatography with conductivity detection (IC-CD)
OSHA Analytical Methods Manual, Method ID188 Ammonia in workplace atmospheres, 2002.

Weight measurement for total dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
902 Preweighed PVC filter, 37 mm, 5 µm

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Weight measurement for total dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
914 PVC filter, 25 mm, preweighed, 5 µm

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.

Weight measurement for total dusts

Method: IRSST - 48-1
Sampling device:
Sampling media required:
#IRSSTDescription
997 PVC filter, 37 mm 5 µm, preweighed, 3-part

Parameters:
Flow rate: 1,5 L/min
TWA sampling volume: 180 L
STEL sampling volume: -
Principle: Gravimetric measurement (Grav)
Precision (%): 4,0
Minimum reported value: 25 µg
Remarks: Additional information is available in Info-Labo 1991-03. The weight measurement method for dusts is by definition non-specific.
IRSST. "Poussière totale". Méthode 48-1. Méthodes analytiques. Montréal: IRSST, 1998.