logo_print

Project IRSST

Design of shoring suitable for urban excavation workAndré Lan, Jean Arteau / IRSST
Denis LeBoeuf, Omar Chaallal / École de technologie supérieure
Jean-Marc Dugré / Jean-Marc Dugré inc.


0095-8360 : Completed

The walls of trenches dug for municipal public works must be vertical, because of the lack of available space and the multiplicity of underground pipes. These walls must be shored if they are not to collapse. This project was undertaken to develop and validate a shoring system that would ensure the safety of excavation work in urban settings. The system allows safe shoring of soils found in the Montreal area to depths of 3.7 metres. In order to promote the use of the system on a wider scale, blueprints, plans, and usage guidelines for all soil types found in Quebec were produced. As a result of this project, municipalities throughout Quebec now have access to a shoring system that protects workers performing public works in trenches.



IRSST publications
Lan, André; Arteau, Jean; Tremblay, Martin; Gamelin, Serge; LeBoeuf, Denis; Chaallal, Omar; Dugré, Marc
Conception d'un étançonnement adapté aux excavations en milieu urbain - Phase 2   (Design of a shoring technique adapted to urban excavations - Phase 2 )
Études et recherches / Rapport  R-235, Montréal, IRSST, 1999, 120 pages. Free download   More Info

Scientific publications and communicationsLan A. 
Boîtes de tranchée pour espaces restreints. Entrevue avec Pierre Gingras
Prévenir aussi, vol. 15, no 2, 2000.

Prévention au travail articles

Excavation en milieu urbain  -  Un système d'étançonnement qui contourne les obstacles et s'adapte à tous les types de sols québécois  -  Volume 13, no 3, p. 17-20. 